This series is a lightweight, compact fetal and maternal monitor, it can meet the need of whole stages of labor (including antepartum and intrapartum monitoring for fetus and mother),It also can be connected to the obstetrical central station.
Features: 1. light and compact design, simple to use front panel controls 2.12.1" TFT Colour screen ,folding 90 degree 3. The system setup can be done very easy and can be stored automatically 4. The internal line 152mm thermal printer can records FHR ,TOCO ,The life exceed over 20 years 5.A standard patient event marker and a clinical event marking button to separately mark Clinical events 6.Auto Fetal movement are available 7. Multi-crystals ,wide beam form, high sensitivity ultrasound transducer ,low ultrasound power, Safer to the fetal 8. AC or LI-battery operated 9. More than 12 hours data storage, then can be played and reprinted 10.Build-in interface to the central nurse station
Technical Specifications
FHR Transducer: Multi-crystals, wide wave beam, pulsed-wave working method, high sensitivity Strength: < 5mW/cm2 Working Frequency: 1.0MHz Signal Processing: Special DSP system and modern recognition Measurement Range: 50~240bpm Alarm Range: High Limit: 160, 170, 180, 190 bpm Low Limit: 90, 100, 110, 120 bpm Maximum Audio Output Power: 1.5 Watt
Measurement Range SYS 6.7~32.0kPa(50~240mmHg) MEAN: 3.4~26.6kPa(25~200mmHg) DIA: 2.0~24.0ka(15~180mmHg)
NIBP Accuracy: ±1.1kPa(±8mmHg)or ±5% of results, taking the bigger one; HR Measurement Range:40bpm~240bpm HR Measure Accuracy: ±2 bpm or ±5% of the results, taking the bigger one. Measure Mode: Manual to start/stop NIBP measurement
Temperature Arrange:0~50 ℃ Resolution: 0.1 ℃ Accuracy: 0.1 ℃( excluded the error caused by transducer)
Display
LCD shows the FHR trace, TOCO tracd, FM, Doctor Event Mark, Time, Volume etc monitor state, and also it can store and playback. Dimension: 350L×320W×85H(mm) Net Weight: 3.5 kg
Environment: Working Environment: Temperature: +5℃ ~ +40℃ Atmospheric Pressure: 86kPa ~ 106kPa Transport and Storage Temperature: Humidity: < 93% Atmospheric Pressure: 86kPa ~ 106kPa
Transducer Acoustic Output: Under the requirements laid down in IEC 1157, 1992, the peak negative acoustic pressure does not exceed 1Mpa.The output beam intensity does not exceed 20mW/cm2 and the spatial-peak temporal average intensity does not exceed 100 mW/cm2. The sound intensity of this monitor will not exceed 5mW/cm2.
GEL
Viscous aqueous non-sensitizing, hypo-allergenic and non-irritating to skin. Bacteriostat (not sterile)