| Physical Specifications | ||||
| Dimension and weight | Dimension | 340mm(W)*280mm(H)*130mm(D) | ||
| Weight | standard configuration: 4 kg | |||
| Operation environment | Power requirements | AC 90-300V, 50/60HZ, 60W | ||
| Power | 90VA | |||
| Temperature | 0-40℃ | |||
| Humidity | 0-93% non-condensing | |||
| Safety | Meet the requirements of IEC60601 series | |||
| Patient range | Adult, neonate and pediatric patients | |||
| Performance Specification | ||||
| Display | 12.1’ (800 x 600 pixel) color TFT LCD screen, support external VGA(option). rolling and refreshing waveform display | |||
| Display mode | Standard, large font, NIBP trend, trend table, full lead ECG, Oxy CRG. | |||
| Interface | Parameter cable interface AC power input socket Network interface External VGA interface for connection of alternate display |
|||
| Battery | 1 internal rechargeable lead-acid battery, 2.0Ah 12V | |||
| Alarm indicator | Visual on-display and integrated alarm light Audible alarm and personated voice reminding alarm |
|||
| Data storage |
720 hours monitoring data 10000NIBP records storage 500 alarm event. |
|||
| Printer | Built-in 50mm thermal printer (option), 3 traces, print speed 12.5mm/s & 25mm/s & 50mm/s print width:50mm |
|||
| Net working | Support connection to central monitoring station through LAN (TCP/IP) or wireless connection | |||
| ECG | ||||
| Leads type | 3/5-lead : I, II, III, aVR, aVL, aVF, V | |||
| Sweep speed | 12.5mm/s, 25mm/s,50mm/s | |||
| Gain selection | ×0.25, ×0.5, ×1, ×2 | |||
| ECG waveform | 3 channels | |||
| Operation mode | Diagnostic, monitor, surgery | |||
| Heart rate range | 15 -350bpm | |||
| Accuracy | 1bpm or ±1% whichever is great | |||
| Alarm range | Audible and visual alarm, adjustable | |||
| ST/ arrhythmia | Real time S-T segment detection, pace detection and arrhythmia analysis | |||
| Protection | Against electrosurgical interference and defibrillation | |||
| Respiration (RESP) | ||||
| Method | Thoracic impedance | |||
| Operation mode | Auto/manual | |||
| Measurement range | Adult: 0-120BrPM; neonatal /pediatric: 0-150BrPM | |||
| Apnea alarm | Yes | |||
| Alarm | Yes, audible and visual alarm ,alarm events recallable | |||
| NIBP | ||||
| Method | Automatic oscillometric | |||
| Operation mode | Manual/Automatic/STAT | |||
| Auto measure time | Adjustable | |||
| Measurement unit | mmHg / kPa selectable | |||
| Test interval | 1-480 minutes | |||
| Measurement range | Adult: 0-300 mmHg ; Child: 0-240 mmHg ; Infant: 0-150 mmHg |
|||
| Over-pressure protection | Double safety protection | |||
| Accuracy of blood pressure measurement | The mean error shall be less than±5mmHg the standard deviation shall be less than 8mmHG |
|||
| Resolution | 1 mmHg | |||
| SpO2 | ||||
| Measurement range | 0%-100% | |||
| Resolution | 1% | |||
| Accuracy | ±2% (70-100%, adult/pediatric, non-motion ) ±3% (70-100%, neonate, non-motion ) ±3% (70-100%, adult/pediatric/neonate, motion ) 0-69% unspecified |
|||
| Alarm range | 1-100% | |||
| Pulse rate | Pulse range: | 0-350bpm | ||
| Accuracy: | ±3bpm(non-motion) ±5bpm(motion ) |
|||
| Temperature (TEMP) | ||||
| TEMP range | 0-50℃ | |||
| Resolution | 0.1 ℃ | |||
| Accuracy | ±0.1℃ (excluding the sensor) | |||
| Channel | Dual-channel. provide T1;T2; △T | |||
| IBP | ||||
| Measurement range | -50-360mmHg | |||
| Channel | 2 channels | |||
| Pressure transducer | Sensitive: 5u V/V mmHg Impedance range: 300-3000 Ω |
|||
| Pressure names | ART, PA, CVP, RAP, LAP, ICP, P1, P2 | |||
| Alarm range | -10-300 mmHg | |||
| PR from IBP | Range & Accuracy: | 25-200bpm ±1bpm or ±1bpm which is greater 201-350bpm ±2% |
||
| Resolution : | 1bpm | |||
| Depth of Anesthesia (BIS) | ||||
| EEG sensitivity | +/- 475μV | |||
| Noise | < 2uVp-p (1-150 Hz) | |||
| CMRR | > 100 dB | |||
| Input impedance | > 50mohm | |||
| Sample rate | 1024 samples/s, 16 bits | |||